Review



multiphor ii apparatus  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92

    Structured Review

    Danaher Inc multiphor ii apparatus
    Multiphor Ii Apparatus, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 92/100, based on 1006 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/Smart-Max+AS-310+device/pmc00333412-62-53-56
    Average 92 stars, based on 1006 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    92/100 stars

    Images

    Related Articles

    Incubation:

    Article Title: Reproductive development of Santa Inês rams during the first year of life: body and testis growth, testosterone concentrations, sperm parameters, age at puberty and seminal plasma proteins.
    Article Snippet: We have investigated the reproductive development of the tropically adapted Santa Inês ram, the most common hair sheep in Brazil.. From 8 to 48 weeks of age, 16 animals were evaluated for body and testis growth, semen parameters, testosterone concentrations and seminal plasma proteins, using two-dimensional SDS-PAGE.. Animals were weaned at 30 days and kept in feedlots thereafter, receiving hay, concentrate (18% of crude protein) and mineral supplement.

    Article Title: Electrophoretic characterization of species of fibronectin bearing sequences from the N-terminal heparin-binding domain in synovial fluid samples from patients with osteoarthritis and rheumatoid arthritis
    Article Snippet: The weights of molecular standards (Gibco BRL, Rockville, MD, USA) are those reported by the manufacturer for prestained proteins. .. Dithiothreitol (18.2 mM), PMSF (2 mM), and aprotinin (0.1 U/ml) were added to the rehydration solution just before the sample, and the mixture was centrifuged at 14,000 g for 15 min and applied via sample cup to a 7-cm isoelectric focusing strip (pre-equilibrated overnight in rehydration solution) for focusing at 20°C in a Multiphor II apparatus (Amersham Pharmacia) at 200 V for 1 min followed by 3500 V for 170 min. After storage at -75°C, strips were incubated for 15 min in 50 mM Tris, pH 8.8, plus 6 M urea, 30% glycerol, 2% SDS, trimmed to exclude ~7 mm from the anodic end, and submitted to 5% SDS–PAGE with an overlay of 0.5% agarose in 25 mM Tris, 192 mM glycine, and 0.1% SDS. .. Dithiothreitol (18.2 mM), PMSF (2 mM), and aprotinin (0.1 U/ml) were added to the rehydration solution just before the sample, and the mixture was centrifuged at 14,000 g for 15 min and applied via sample cup to a 7-cm isoelectric focusing strip (pre-equilibrated overnight in rehydration solution) for focusing at 20°C in a Multiphor II apparatus (Amersham Pharmacia) at 200 V for 1 min followed by 3500 V for 170 min. After storage at -75°C, strips were incubated for 15 min in 50 mM Tris, pH 8.8, plus 6 M urea, 30% glycerol, 2% SDS, trimmed to exclude ~7 mm from the anodic end, and submitted to 5% SDS–PAGE with an overlay of 0.5% agarose in 25 mM Tris, 192 mM glycine, and 0.1% SDS.

    Stripping Membranes:

    Article Title: Electrophoretic characterization of species of fibronectin bearing sequences from the N-terminal heparin-binding domain in synovial fluid samples from patients with osteoarthritis and rheumatoid arthritis
    Article Snippet: The weights of molecular standards (Gibco BRL, Rockville, MD, USA) are those reported by the manufacturer for prestained proteins. .. Dithiothreitol (18.2 mM), PMSF (2 mM), and aprotinin (0.1 U/ml) were added to the rehydration solution just before the sample, and the mixture was centrifuged at 14,000 g for 15 min and applied via sample cup to a 7-cm isoelectric focusing strip (pre-equilibrated overnight in rehydration solution) for focusing at 20°C in a Multiphor II apparatus (Amersham Pharmacia) at 200 V for 1 min followed by 3500 V for 170 min. After storage at -75°C, strips were incubated for 15 min in 50 mM Tris, pH 8.8, plus 6 M urea, 30% glycerol, 2% SDS, trimmed to exclude ~7 mm from the anodic end, and submitted to 5% SDS–PAGE with an overlay of 0.5% agarose in 25 mM Tris, 192 mM glycine, and 0.1% SDS. .. Dithiothreitol (18.2 mM), PMSF (2 mM), and aprotinin (0.1 U/ml) were added to the rehydration solution just before the sample, and the mixture was centrifuged at 14,000 g for 15 min and applied via sample cup to a 7-cm isoelectric focusing strip (pre-equilibrated overnight in rehydration solution) for focusing at 20°C in a Multiphor II apparatus (Amersham Pharmacia) at 200 V for 1 min followed by 3500 V for 170 min. After storage at -75°C, strips were incubated for 15 min in 50 mM Tris, pH 8.8, plus 6 M urea, 30% glycerol, 2% SDS, trimmed to exclude ~7 mm from the anodic end, and submitted to 5% SDS–PAGE with an overlay of 0.5% agarose in 25 mM Tris, 192 mM glycine, and 0.1% SDS.

    Modification:

    Article Title: Proteomic Signature of Fatty Acid Biosynthesis Inhibition Available for In Vivo Mechanism-of-Action Studies
    Article Snippet: .. Modified according to Fujita et al. (9) with permission of the publisher. on July 17, 2012 by U N IV O F S U S S E X http://aac.asm .org/ D ow nloaded from rehydration for 18 h. Isoelectric focusing was carried out using a Multiphor II apparatus (GE Healthcare), applying the following gradient: 0 to 500 V for 1 kVh, 500 V for 0.02 kVh, 500 to 3,500 V for 3 kVh, and 3,500 V for 57 kVh at 20°C. ..

    Electrofocusing:

    Article Title: Proteomic analyses of age related changes in A.BY/SnJ mouse hearts
    Article Snippet: Linear pH 4–7, 24 cm IPG strips (GE Healthcare) were rehydrated overnight in rehydration solution (urea 8 M, thiourea 2 M, pharmalyte 3–10 and 10 × dithiothreitol (DTT)) containing two labeled samples (Cy3 and Cy5, each 50 μg) and the corresponding internal standard (Cy2, 50 μg) for first dimension separation. .. The isoelectric focusing (IEF) was performed using a Multiphor II apparatus (GE Healthcare) with voltages ranging from 500 V to 3500 V for 17.50 h as suggested by the manufacturer. ..

    other:

    Article Title: Differential protein expression in Colletotrichum acutatum : changes associated with reactive oxygen species and nitrogen starvation implicated in pathogenicity on strawberry
    Article Snippet: For measurement of ROS upon nutritional induction, 80 μL conidia (10 5 conidia/mL) were resuspended in Reg medium or in water containing 5 m m of one of the various nitrogen‐containing compounds tested (glutamine, urea, nitrate, nitrite or ammonium sulphate), and allowed to germinate in Microtest plates (Sarstedt, Inc., Newton, NC) for various times within a 16‐h period, before staining for 1 h with the H 2 DCFDA probe.



    Similar Products

    90
    Amersham Life Sciences Inc multiphor ii apparatus
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Multiphor Ii Apparatus, supplied by Amersham Life Sciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/multiphor+ii+system/pmc10755757-12-50-53
    Average 90 stars, based on 1 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Amersham Pharmacia Biotech Ltd multiphor ii apparatus
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Multiphor Ii Apparatus, supplied by Amersham Pharmacia Biotech Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/multiphor+ii+system/pm38002494-116-6-9
    Average 90 stars, based on 1 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    92
    Danaher Inc multiphor ii apparatus
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Multiphor Ii Apparatus, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/Smart-Max+AS-310+device/pmc00333412-62-53-56
    Average 92 stars, based on 1 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    92/100 stars
      Buy from Supplier

    90
    SERVA Electrophoresis multiphor ii apparatus
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Multiphor Ii Apparatus, supplied by SERVA Electrophoresis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/multiphor+ii+apparatus/10__1128_slash_aac__02315___18-117-38-24
    Average 90 stars, based on 1 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Pharmacia LKB Biotechnology Inc multiphor ii apparatus
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Multiphor Ii Apparatus, supplied by Pharmacia LKB Biotechnology Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/multiphor+ii+system/pm29342175-70-38-41
    Average 90 stars, based on 1 article reviews
    multiphor ii apparatus - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Amersham Life Sciences Inc semi-dry blotting apparatus multiphore ii
    Specification of the Relevant Instrumental Techniques for LF Characterization
    Semi Dry Blotting Apparatus Multiphore Ii, supplied by Amersham Life Sciences Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiphor+ii+apparatus/semi+dry+blotting+apparatus+multiphore+ii/pm28854803-91-18-23
    Average 90 stars, based on 1 article reviews
    semi-dry blotting apparatus multiphore ii - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Specification of the Relevant Instrumental Techniques for LF Characterization

    Journal: Journal of Agricultural and Food Chemistry

    Article Title: The Multifaceted Roles of Bovine Lactoferrin: Molecular Structure, Isolation Methods, Analytical Characteristics, and Biological Properties

    doi: 10.1021/acs.jafc.3c06887

    Figure Lengend Snippet: Specification of the Relevant Instrumental Techniques for LF Characterization

    Article Snippet: , IEF , electromigration , Different pI values determined by IEF also might be a matter of the selected separation conditions, e.g. the type of carrier ampholyte (CA), pI marker, buffer composition, and separation time. The possibility of distinction of several LF fractions is based on their pI values. , Multiphor II apparatus (Amersham, Freiburg, Germany); precast gels Servalyt and Blank precotes (Serva, Germany); gel parameters, 126 × 125 × 0.3 mm; temperature, 5–8 °C; voltage, 2000 V; current, 6 mA; power, 12 W , ( , ) .

    Techniques: Isolation, Glycoproteomics, Staining, Mass Spectrometry, Concentration Assay, Spectrophotometry, Clinical Proteomics, Zeta Potential Analyzer, Marker, Spectroscopy, Software, Raman Spectroscopy, Functional Assay, Fluorescence, Sequencing, Single Particle, Microscopy, Chromatography, Solvent, Evaporation, Differential Scanning Calorimetry, Injection